Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MSI-EM | ||||||
Application | Monitoring of safety functions | ||||||
Number of safe I/Os | 4 OUT relays | ||||||
Functions | |||||||
Functions | Monitoring of all safe functions in machines and systems, Extension module for the MSI 200 programmable safety controller, Extension with 4 safe relay outputs | ||||||
Characteristic parameters | |||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Performance Level (PL) | e, EN ISO 13849-1 | ||||||
PFHD | 3E-11 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 4, EN ISO 13849 | ||||||
B10d at DC13 (inductive load) | 780,000 number of cycles | ||||||
B10d at AC15 (inductive load) | 1,960,000 number of cycles | ||||||
Electrical data | |||||||
Protective circuit | Overvoltage protection | ||||||
Performance data | |||||||
Supply voltage UB | 24 V, DC, -15 ... 10 % | ||||||
Overvoltage category | III | ||||||
Protective circuit | Overvoltage protection | ||||||
Outputs | |||||||
Number of signal outputs | 4 Piece(s) | ||||||
Output data | |||||||
Status indicator | 2 LEDs (green, red) | ||||||
Limiting continuous current | 4 A | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Safety-related switching outputs | |||||||
Type | Safety-related switching output OSSD | ||||||
Voltage type | AC/DC, DC | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Safety-related switching output 1 | |||||||
Switching element | Relay, NO | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Safety-related switching output 2 | |||||||
Switching element | Relay, NO | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Safety-related switching output 3 | |||||||
Switching element | Relay, NO | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Safety-related switching output 4 | |||||||
Switching element | Relay, NO | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Signal outputs | |||||||
Nominal voltage | 24 V DC, (A1/A2) | ||||||
Limiting continuous current | 50 mA | ||||||
Number of signal outputs | 4 Piece(s) | ||||||
Protective circuit | Overvoltage protection | ||||||
Timing | |||||||
Readiness delay | 10,000 ms | ||||||
Connection | |||||||